<br><b>DuPont™ ArmorWall™ Plus Fire-Rated (FR) Structural Insulated Sheathing (SIS)</b> is an ICC listed (ESL-1302, ESL-1306, ESL-1442, ESL-1536, and ESL-1543), high strength, fire-resistant exterior wall sheathing product. <b>ArmorWall™ Plus FR SIS</b> offers a factory-applied, high quality air and water-resistive barrier. Once seams and fasteners have been sealed the enclosure may be considered “dried-in”, allowing interior construction to commence regardless of final exterior finish status. <br><br>ArmorWall™ Plus FR SIS incorporates five traditional building enclosure elements into a single panel product: structural sheathing, fire-resistance, air barrier, water-resistive barrier, and a high-performance continuous insulation layer. The <b>five-in-one</b> system of <b>ArmorWall™ Plus FR SIS</b> can replace several traditional individual components, making it a cost-saving and labor-reducing option compared to traditional, individual components.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Available Sizes

Total Panel Thickness Sheathing Thickness Insulation Thickness R-Value Size Net Weight<sup>1</sup>
2" 1/2" 1 1/2" R10 4' x 8' (32 sqft/sheet) 103 lbs
2 3/4" 1/2" 2 1/4" R15 4' x 8' (32 sqft/sheet) 110 lbs
3 3/4" 1/2" 3 1/4" R21 4' x 8' (32 sqft/sheet) 115 lbs

1Average panel weight may vary based upon environmental conditions.

 
 
 

Physical Properties

Property Method Value
Air Leakage Resistance ASTM E2357 Pass
Air Infiltration at 75 Pa ASTM E283 0.01 cfm/ft2 (0.1 L/s/m2)
Air Infiltration at 300 Pa ASTM E283 0.04 cfm/ft2 (0.2L/s/m2)
Fastener Sealability2 ASTM D1970 Pass
Fire Resistance NFPA 2853 Pass
Flame Spread/Smoke Developed Index (MgO Board) ASTM E84 0 / 0
Flame Spread/Smoke Developed Index (insulation) ASTM E84 20 / 200
Foam Compression Range ASTM D1621 30 psi
Mold and Mildew ASTM C1338 Pass
Thermal Resistance ASTM C518 6.5 per inch
Vapor Permeance (of 2" panel) ASTM E96, Procedure A 0.5 Perms (grains/hr in Hg ft2)
Water Penetration at 6.27 psf (300 Pa) ASTM 3311 Pass
Cladding Attachment Figures
Fastener Shear in Sheathing Only ASTM D176145 519 lbs
Fastener Pull Through ASTM D176145 505.2 lbs
Fastener Withdrawal Capacity ASTM D176145 284 lbs

1Total test duration two continuous hours.

2ArmorWall™ Plus FR SIS is self-sealing around cladding attachment fasteners.

3ArmorWall™ Plus FR SIS passes NFPA 285 attached directly to the stud framing allowing most cladding installed to its exterior as inclusive to the NFPA 285 approved assembly

4Fastener data reflects attachment to the panel not attachment to structure.

Shear Properties

Fastener Type Min. Fastener Penetration into Framing Panel Applied Direct to Framing (Fastener Spacing at Panel Edges in Inches) Panel Applied Direct to Framing w/ 1/2" Gypsum on Opposite Face (Fastener Spacing at Panel Edges in Inches)
Shear (lbs/ft) w/ Framing of Douglas - Fir - Larch or Southern Pine with blocked perimeters
12" 6" 4" 6"
#14-13 1" 301 lbf (RNV) 437.5 lbf (RNV) 537.5 lbf (RNV) 570 lbf (RNV)
#14-13 1" 150 lbf (ASD) 218.75 lbf (ASD) 268.75 lbf (ASD) 285 lbf (ASD)
#14-13 1" 240 lbf (LFRD) 350 lbf (LRFD) 430 lbf (LRFD) 456 lbf (LRFD)

Deflection Properties

Property Test Method Stud Thickness3 Span Results
L/240 TAS 202-941 18 ga 86" +113/-95 psf (+5400/-4560 Pa)
L/240 TAS 202-941 20 ga 86" +60/-40 psf (+2880/-1920 Pa)
L/360 TAS 202-941 18 ga 86" +113/-75 psf (+5400/-3600 Pa)
L/360 TAS 202-941 20 ga 86" +60/-25 psf (+2880/-1200 Pa)
TAS 203-942 18 ga +113/-95 psf (+5400/-4560 Pa)
TAS 203-942 20 ga +60/-40 psf (+2880/-1920 Pa)

1Impact and Non-impact Resistance Building Envelope Components Using Uniform Static Air Pressure per Florida Building Code 6 Edition (2017) Section 1604

2Criteria for Testing Products Subject to Cyclic Wind Pressure Loading per Florida Building Code 6 Edition (2017) Section 1604

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 