As an insulation and interior finish system for walls and ceilings, DuPont™ Thermax™ Heavy Duty Insulation stands up to tough indoor challenges with a fiberglass core and aesthestic white thermoset-coated aluminum facing.
Thermax™ Heavy Duty
DuPont™ Thermax™ Heavy Duty Insulation is an easy-to-install, easy-to-clean insulation and interior finish system for walls and ceilings in metal and concrete or masonry buildings, as governed by building codes. It consists of a glass-fiber-reinforced polyisocyanurate foam core faced with nominal 4-mil embossed white thermoset-coated aluminum on one side and 1.25-mil embossed aluminum on the other. The tough white embossed aluminum surface makes it a durable insulation/finish choice for use in moderate-impact areas, and it can be pressure-washed up to 2,000 psi with a 15-degree or greater spray tip (at 3’ minimum distance). The robust facers help prevent water and water vapor intrusion into the insulation foam, allowing it to stabilize at a higher R-Value for high, long-term thermal resistance. Used in conjunction with the appropriate joint closure system for the application, DuPont™ Thermax™ Heavy Duty Insulation – with its low perm rating – can help to reduce moisture condensation within and behind the insulation.
DuPont™ Thermax™ Brand insulation delivers wall performance you can count on. It’s ready to meet your toughest building challenges – both outside and inside the wall – with a robust polyiso insulation product line and an R-Value that’s proven to be consistent over time and a range of temperatures.
Available Sizes
Standard Thermax™ insulation board dimensions are 4'x8'. Custom lengths are available up to 30'. Please contact your local DuPont representative for additional availability details or call our product support team at 1-833-338-7668
Easy to cut, handle, and install |
|
Aesthetically pleasing white finish for interior applications |
|
Moisture resistant |
|
Long-term thermal resistance |
|
  | Method | Unit | Value |
---|---|---|---|
R-Value (Thermal Resistance at 75°F Mean Temperature)<sup></sup> | ASTM C518 | ft2•hr•°F/Btu | 6.9 |
R-Value (Thermal Resistance at 40°F Mean Temperature)<sup></sup> | ASTM C518 | ft2•hr•°F/Btu | 7.2 |
Compressive Strength<sup>3</sup> | ASTM D1621 | Psi, min (kPa) | 25 (170) |
Water Absorption<sup></sup> | ASTM C209 | % by volume, max. | 0.1 |
Water Vapor Permeance<sup></sup> | ASTM E96 | perm, max | <0.01 |
Flexural Strength<sup></sup> | ASTM C203 | Psi, min (kPa) | 40 (275) |